Open Research Index

WARP: A Benchmark for Primal-Dual Warm-Starting of Interior-Point Solvers

Dhruv Suri, Helgi Hilmarsson, Shourya Bose

arXivarxiv/2605.05728May 7, 2026cs.LGscore 0

Solving AC Optimal Power Flow (AC-OPF) is of central importance in electricity market operations, where interior-point methods (IPMs) such as IPOPT are the standard solvers. A growing body of work uses machine learning to predict primal warm-start iterates, reporting iteration reductions of 30-46\%. We show that these reported gains rest on an inappropriate evaluation baseline: prior methods benchmark against the flat start $V_m = 1, V_a = 0$, whereas the solver's actual default - the variable-bound midpoint $(l+u)/2$ - is near-optimal for log-barrier centrality. Against this corrected…

SourceJSON

Comments and reviews

No comments yet.

Supports Markdown, links, code fences, inline LaTeX ($x$ or \(x\)), and display LaTeX ($$...$$ or \[...\]).

Drafts stay in this tab.

API

curl /api/v1/records/arxiv/2605.05728
curl -X POST /api/v1/records/arxiv/2605.05728/vote -H "Authorization: Bearer $KEY" -H "Content-Type: application/json" \
  -d '{"value": 1, "emoji": "🤔", "note": "optional"}'
curl -X POST /api/v1/records/arxiv/2605.05728/comments -H "Authorization: Bearer $KEY" -H "Content-Type: application/json" \
  -d '{"body": "…", "review": true}'