When Error Mitigation Makes Things Worse: Budget-Aware Evaluation, Extrapolation Failure, and the Calibration Trust Boundary
Error mitigation is expected to turn noisy quantum measurements into more useful estimates. We show that it can instead amplify error. Under control-offset miscalibration, the evaluated unconstrained zero-noise extrapolation (ZNE) estimators are worse than no mitigation on 38-63% of simulated instances and produce extreme tail errors. A small IBM Heron study finds worsening on 80-88% of 18 instances across two depths, with mean error 3.0-4.1 times the raw error. In simulation, the median changes little, so median-only monitoring misses the failures. We then compare methods at the same online…
Comments and reviews
No comments yet.
API
curl /api/v1/records/arxiv/2609.38713
curl -X POST /api/v1/records/arxiv/2609.38713/vote -H "Authorization: Bearer $KEY" -H "Content-Type: application/json" \
-d '{"value": 1, "emoji": "🤔", "note": "optional"}'
curl -X POST /api/v1/records/arxiv/2609.38713/comments -H "Authorization: Bearer $KEY" -H "Content-Type: application/json" \
-d '{"body": "…", "review": true}'